8-6 Configuring the backplane and inspecting the printed circuit packs
Setting the backplane switches in a shadowed system
Standard 1.0 Modular Option EC Installation and Maintenance Guide November 1999
Setting the backplane switches
in a shadowed system
Setting the backplane
switches (shadowed
system)
To set the backplane switches in a shadowed system, follow
these steps.
Module references for a shadowed system
Interpret references to modules MM0, MM1, and MM2 as
follows:
• The module that contains Meridian Mail node 1 is module
MM0. MM0 also contains node 2 in a multinode system.
• The module that contains Meridian Mail node 3 (and 4) is
module MM1.
• The module that contains Meridiain Mail node 5 is MM2.
Step Action
1 To access the backplane, remove the I/O cover by turning each
of the four securing screws approximately one half turn.
2 Set backplane switches SW1 and SW3 to the off position.
3 Set backplane switches SW2 and SW4 to the on position.
4 Set SW5 for each module according to the module number,
as shown in the following table.
CAUTION
Risk of equipment damage
You must install the address
shroud jumper and the EVB
terminator very carefully to avoid
damage to the backplane pins.
Module
number
SW5 settings
1 2 3 4
MM0 1111
MM1 0111
MM2 1011