16-22 Troubleshooting startup problems
Power problems
Standard 1.0 Modular Option EC Installation and Maintenance Guide November 1999
Resolving AC system
power problems
To resolve AC system power problems, follow these steps.
Testing the power
harness and pedestal
power supply
To test the power harness and pedestal power supply, follow
these steps.
Step Action
1 Remove the front doors from all modules in the system.
2 If no LEDs are lit on any module above a certain module, go to
the procedure that follows and test the pedestal power supply
and power harness at the lowest module that has no lit LEDs.
3 If no LEDs, including the LEDs on the CEPS, are lit on a single
module or on a single side of a module, go to “Testing the
CEPS” on page 16-23.
Note:
A side of a module that contains a power supply but no
PCPs or disk drives will indicate a CEPS failure.
Step Action
1 Check the AC voltage at the CEPS connectors (see “Front view
of module, CEPS removed” on page 16-23).
a. Switch off both breakers on the module.
b. Remove both CEPS.
c. Check the voltage at the pins shown in “Front view of
module, CEPS removed” on page 16-23.
d. If the voltage is incorrect, refer to
SL-1 Fault Clearing
(NTP 553-3001-510).
2 If the voltage is correct, continue with “Testing the CEPS” on
page 16-23.