Troubleshooting startup problems 16-27
System fails to boot completely
Standard 1.0 Modular Option EC Installation and Maintenance Guide November 1999
Troubleshooting stage
4 bootup failure
Failure during this stage of bootup can indicate that the system
can initialize the SCSI disk but not boot from it. Follow these
steps.
Troubleshooting stage
5, 6, or 7 bootup
failure
Stages 5 and 6 take up to five seconds each. Stage 7 takes up to
two minutes. If the bootup fails at this point, Mail programs
were read incorrectly from the disk or the program on the disk is
incorrect or corrupted. Follow these steps.
Troubleshooting stage
8 bootup failure
To troubleshoot stage 8 bootup failure, follow these steps.
Step Action
1 Perform the checks in “Troubleshooting stage 3 bootup failure—
disk subsystem check” on page 16-26.
2 Check that the SCSI devices are unterminated as described in
Chapter 7.
3 Check that the tape drive is unterminated as described in
Chapter 7.
4 If the bootup display shows error messages such as “bus error,”
there may be a serious problem with the SCSI disk. Contact
your Nortel Networks support organization.
Step Action
1 Attempt to reboot the system.
If the problem persists (the bootup fails at the same point),
there may be a serious problem with the SCSI disk.
2 Contact your Nortel Networks support organization.
Step Action
1 Check the terminal output during this stage.
2 If there is indication that the PRM failed to load, contact your
Nortel Networks support organization.