Troubleshooting operational problems 17-5
System-level problems
Standard 1.0 Modular Option EC Installation and Maintenance Guide November 1999
3 Courtesy down the system, then reactivate it. Refer to the
System Administration Guide
(NTP 555-7001-30x) for
instructions on how to courtesy down and reactivate the
system.
4 Verify that the cabling from the MSDL/ESDI card to Meridian
Mail is connected and secured to the correct MSDL/ESDI port.
5 Verify that the correct database programming has been used
for the MSDL/ESDI dataport in Meridian Mail.
Refer to Chapter 12 for details on programming and checking
the ESDI/MSDL dataport.
6 Replace the following, one at a time: Enhanced MMP40 (or
MMP40) card, utility cards, and any filter connectors.
7 Determine if any nodes show Faulty or OutOfService status.
If any nodes are in Faulty or OutOfService status:
a. Verify that all cards and disk drives are properly seated.
b. Refer to “System fails to boot completely” on page 16-24.
c. Check for a disk subsystem problem (Chapter 16 and
Chapter 19).
d. Check if Meridian Mail is communicating with SCSI address
0, 1, or 2 (Chapter 19).
8 Determine if any of the voice cards show Faulty or
OutOfService status.
If a voice card shows Faulty or OutOfService status:
a. Disable the card. For detailed instructions on disabling the
card, refer to the
System Administration Guide.
b. Perform out-of-service diagnostics as described in the
System Administration Guide
(NTP 555-7001-30x).
c. Reenable the card.
d. If the card fails out-of-service diagnostics or remains faulty,
replace it.
Step Action