Troubleshooting operational problems 17-23
Silent channels
Standard 1.0 Modular Option EC Installation and Maintenance Guide November 1999
Silent channel—calls
have no voice or SEER
response
When you have a silent channel where calls have no voice or
SEER response, follow these steps.
5 Check the QPC414 in the Meridian 1:
a. Disable and reseat the QPC414.
b. Reenable the QPC414.
c. Initialize the Meridian 1.
Note:
This step will suspend call processing. Avoid it during
peak business hours.
6 Replace the network loop cable.
7 Replace the voice card.
8 If these procedures are unsuccessful, contact your Nortel
Networks support organization.
Step Action
Step Action
1 Determine if ERR 3036 or ERR 3037 appeared on the Meridian
1 console. See the
X11 Input/Output Guide
(553-3001-400) for
an explanation of the error message.
2 If a new network loop was assigned for Meridian Mail in the
Meridian 1 configuration record, verify that the Meridian 1 was
manually initialized.
3 If these procedures are unsuccessful, contact your Nortel
Networks support organization.