Configuring the Meridian 1 12-11
Establishing the AML using an ESDI card
Standard 1.0 Modular Option EC Installation and Maintenance Guide November 1999
Overlay 17—ESDI and AML configuration (X11 Release 18
or later)
Prompts Responses Description
REQ CHG Change
TYPE CFN Configuration data block
ADAN NEW AML xx
(range is 0–15)
The response “NEW AML xx”
creates an AML with a link number
xx. The link number can be any
number from 0–15.
The link number must match the
physical address switch on the
card (DNUM).
CTYP MSDL or ESDI Card type
DNUM 0–15 Device number for the AML port.
Use the same number that you
used for the AML number. This
makes it easier to remember both
numbers.
The device number must match
the physical address switch on the
card.
PORT x (MSDL only) Port number in the
range 0–3
DES aaa...a AML port designation. This can be
any alphanumeric string up to 16
characters: 0–9 and A–Z
(uppercase only) are allowed.
Characters * and # are not
allowed.
BPS 9600 Baud rate
PARM (R232 DCE) (MSDL only) Interface and
transmission mode
CLOK EXT Internal or external clock. Source
of primary clock is either internal
or external. (ESDI only)
IADR (3) Individual Address for the datalink
HDLC protocol. The IADR and
RADR prompts must be
coordinated with the far-end. If
IADR is defined as 3, then RADR
must be 1. Default is 1 prior to
Release 18.