16-28 Troubleshooting startup problems
System fails to boot completely
Standard 1.0 Modular Option EC Installation and Maintenance Guide November 1999
Troubleshooting stage
9 bootup failure
To troubleshoot stage 9 bootup failure, follow these steps.
Troubleshooting stage
10 bootup failure
This stage normally takes approximately five minutes.
However, on a multi-node system, if a remote node is having
problems booting up, then this stage can take as long as
20 minutes. Follow these steps.
Step Action
1 Check the terminal output during this stage.
2 If there is indication that SEERs may be lost, power down the
system and power it back up to reset the system.
3 If the system has multiple nodes and the output indicates that
some of the non-prime nodes are not responding, check the
power supply for those nodes. See “Preliminary action” on
page 16-18 and “Testing the DCEPS” on page 16-21 (DC
system) or “Testing the CEPS” on page 16-23 (AC system).
4 Power the system down, then power it back up to reset the
system. If the boot still fails at the same point, replace the
Enhanced MMP40 (or MMP40) cards of the affected nodes.
5 If the problem occurs on all the remote nodes, perform the
system bus diagnostics (“Performing system bus diagnostics”
on page 16-31).
Step Action
1 Check the SEER output from the printer for problems with
remote nodes.
2 If one or more remote nodes (but not all) are having problems,
power down and up to reset the system.
Note:
If the problem is occurring on all nodes, follow
“Performing system bus diagnostics” on page 16-31.
3 If the problem persists, replace the Enhanced MMP40
(or MMP40) cards of the affected nodes.