Installing intramodule and intermodule cabling 9-9
Installing RS-232 cables
Standard 1.0 Modular Option EC Installation and Maintenance Guide November 1999
Installing RS-232 cables
Introduction
You need two I/O-to-backplane cables (NT6P0123 or
NT6P0114), one 5-port fanout cable (NT6P0109), and one
4-port fanout cable (NT6P0110) for each module, except for the
last module in a 5-node shadowed system that does not use the
4-port cable. Refer to “Intermodule cabling for a two-module
system” on page 9-13.
Installing I/O-to-
backplane cables
To install the I/O-to-backplane cables, follow these steps.
Installing the alarm/
modem cable
You need one alarm/modem cable (NT6P0112). Refer to
“Backplane to I/O panel and next module cabling” on page 9-7.
To install the alarm/modem cable, follow these steps.
Step Action
1 Connect an I/O-to-backplane cable from the I/O position on
shroud S5 to the 5-RS-232 connector on the inside of the right
I/O panel.
2 Connect the end of an I/O-to-backplane cable from the I/O
position on the shroud S7 to the 4-port RS-232 connector on
the inside of the left I/O panel.
Note:
The connectors on the I/O panels are labeled differently
on the inside and outside of the panel. Ensure that the I/O
backplane cable is connected correctly. (See “Backplane to I/O
panel and next module cabling” on page 9-7.)
3 4-port RS-232 cable
Connect the single connector end of the 4-port fanout cable to
the 4-RS-232 connector on the outside of the left I/O panel.
4 5-port RS-232 cable
Connect the single connector end of the 5-port fanout cable to
the 5-RS-232 connector on the outside of the right I/O panel.