Installing, cabling, and configuring peripheral devices 10-27
Bix block cabling for peripheral devices
Standard 1.0 Modular Option EC Installation and Maintenance Guide November 1999
Bix block cabling for peripheral devices
Introduction
The following section outlines the Bix block designations and
cabling for the peripheral devices. You can cable peripherals
through the main distribution frame (MDF) as an alternative to
using the 4- and 5-port fanout cables for any module; this is the
normal method of cabling the alarm connections from module
MM0. See “Connecting the alarm to the main distribution
frame” on page 10-30.
To wire any of these three sets of connections to the MDF,
install an NEA25B cable to the appropriate Meridian Mail I/O
panel connector.
ALM/MDM and 4- and 5-port RS-232 Bix block tip, ring, pin,
and pair colors” on page 10-28 lists tip, ring, pin, and pair color
information for the ALM/MDM cable, and the equivalents for
the 4- and 5-port fanout cables.
Alarms
Two Form-C dry contact relays are provided for connection to
customer-provided alarms. Each relay contact is rated at 0.5
amperes and 150 V DC. The major alarm contacts can be
triggered by the Enhanced MMP40 processor, a board reset, a
power off condition, or a watchdog timeout (which has a fixed
128-second timeout interval).