11-18 Installing the Meridian Mail to PBX interface
Installing the multipurpose serial data link card
Standard 1.0 Modular Option EC Installation and Maintenance Guide November 1999
6 Set the switches on the MSDL card for the port you are going to
use for the AML according to the settings shown in the following
table.
7 Set the S9 and S10 switches on the MSDL to the DNUM that
you chose in step 4. For example, if you chose device number
10, set S9 to1 and S10 to 0.
8 Disable the card, using the [Disable Node] softkey on the
System Status screen. For more information on how to disable
an I/O card, refer to the “System Status and Maintenance”
chapter in your administration guide.
9 Install the card in the Meridian 1, in a loop (LP) slot on a
common equipment (CE) shelf.
10 Observe the red LED on the MSDL faceplate.
The LED should flash three times, and then stay on until the
card is configured and enabled in the software. If the LED does
not behave in this pattern, replace the card.
11 Enable the card, using the [Enable Node] softkey on the
System Status screen. For more information on how to enable
an I/O card, refer to the “System Status and Maintenance”
chapter in your administration guide.
Step Action
Port Switch Switch
Port 0 S4 = OFF S8 = OFF
Port 1 S3 = OFF S7 = OFF
Port 2 S2 = OFF S6 = OFF
Port 3 S1 = OFF S5 = OFF