Troubleshooting startup problems 16-29
System fails to boot completely
Standard 1.0 Modular Option EC Installation and Maintenance Guide November 1999
Troubleshooting stage
11 bootup failure
If the bootup fails during this stage, follow these steps.
Step Action
1 Check the SEERs for problems when loading programs. If you
see any SEERs, then follow the actions suggested in the
Maintenance Messages (SEERs)
Guide
(NTP 555-7001-510).
2 Observe the terminal output during stages 7, 8, and 9 for any
indications that node 1 is not InService. If there are indications
that node 1 is not InService, contact your Nortel Networks
support organization.
3 If node 1 is InService but the system will not progress past
stage 10, then
a. Replace the Enhanced MMP40 (or MMP40) card in node 1.
b. Check for Meridian Mail power problems.
DC system—see “Preliminary action” on page 16-18,
“Resolving DC system power problems” on page 16-18,
“Testing the pedestal power supply” on page 16-19, “Testing the
power harness” on page 16-20, and “Testing the DCEPS” on
page 16-21.
AC system—see “Preliminary action” on page 16-18,
“Resolving AC system power problems” on page 16-22,
“Testing the power harness and pedestal power supply” on
page 16-22, and “Testing the CEPS” on page 16-23.
c. If the problem is occurring on all nodes, then follow
“Performing system bus diagnostics” on page 16-31.