
Troubleshooting operational problems 17-17
AML troubleshooting procedures
Standard 1.0 Modular Option EC Installation and Maintenance Guide November 1999
AML troubleshooting procedures
Introduction
The procedures in this section describe how to correct
problems with the link between the Meridian Mail Modular
Option EC and the Meridian 1.
System status shows
Faulty link to PBX
To correct this problem, follow these steps.
Step Action
1 Verify that the AML cable is in place and secure.
2 Check that the Meridian 1 has been properly configured (refer
to Chapter 12, “Configuring the Meridian 1”).
3 Check other hardware addresses such as ESDI ports or
D-channel ports to ensure they are not assigned the same
hardware address as the MSDL/ESDI ports.
4 Verify that the MSDL switch settings or ESDI switch settings are
correct, and card option plugs are installed in the correct
locations.
5 Program the unassigned port of the ESDI card in the Meridian
1 configuration record and perform the self-test as outlined in
Overlay 48. Refer to Chapter 12 for details.
Note:
The MSDL requires the self-test only.
a. Disable the MSDL/ESDI port.
b. Perform autosetup (ACMS) for the MSDL/ESDI port.
6 Check the PBX to make sure traffic is flowing by placing a
phone call to Meridian Mail and watching the DSP Port Status
screen (which you can access from the Meridian Mail Logon
screen).
Comentarios a estos manuales