Troubleshooting operational problems 17-7
AML problems
Standard 1.0 Modular Option EC Installation and Maintenance Guide November 1999
AML problems
Introduction
The AML consists of several hardware and software
components. Failure of any of these components affects the
operation of the link. When a faulty link is detected, the
Meridian 1 puts the link in a “Down” state, and all calls are
routed to the DN defined in the Night Call Forward (NCFW)
field of the main Meridian Mail ACD Queue.
Communication between the Meridian 1 and Meridian Mail
is lost until the link is restored.
The following types of error messages are generated on the
Meridian 1 maintenance TTY:
CSA xxx AML alarm messages
ESDA xxx ESDI/MSDL failure messages
ESDI/MSDL xxx ESDI/MSDL failure messages
LNK xxx errors related to user commands in
Overlay 48 where xxx represents the
error number and associated
information
Refer to the appropriate section for the type of error message
that appears on the TTY.
Hardware-related
problems
Check the status of the hardware.
Verify that the Meridian 1 has the correct software
options for the AML application.
Examine the SEER messages.
Examine the cable connections between the ESDI/
MSDL card and the Meridian Mail Enhanced MMP40
(or MMP40) RS-232 connector.
Examine the bootROM messages that appear when
Meridian Mail is powered on.
Verify that the option plugs on the ESDI card are in the
correct sockets; verify the switch settings on the MSDL
card. See Chapter 11, “Installing the Meridian Mail to
PBX interface,” for details.