12-30 Configuring the Meridian 1
Programming the network loop
Standard 1.0 Modular Option EC Installation and Maintenance Guide November 1999
Verifying the network
loop operation
To verify the network loop, follow these steps.
Note: C-processors do not require initialization. Use the ENLL
xx and STAT xx commands in Overlay 32 to enable and verify
the specific network loop.
.
Step Action
1 Initialize the switch manually by pressing the MAN INT button
on the CPU card. If you have a dual CPU, press the main MAN
INT button on the active CPU.
This should automatically enable the loop, and the
corresponding LED should extinguish. This indicates that the
loop is enabled.
2 Load Program 30 to verify the status (STAT), and test (LOOP)
the network loop of
x
(where
x
represents the particular loop
being tested). Follow the acceptance testing procedure listed in
the
Circuit Card Installation
(NTP 553-3001-211).
3 If you receive an error message, refer to the
X11 Input/Output
Guide
(NTP 553-3001-400) to troubleshoot and correct the
problem.
If you receive an OK, the loop connection is successfully
established.