12-22 Configuring the Meridian 1
Defining Meridian Mail in the customer data block
Standard 1.0 Modular Option EC Installation and Maintenance Guide November 1999
Overlay 15—Customer data block, Release 21 and later
As of Release 21, you can directly access a given data block by
entering the first three letters of a gate opener. Below are the
required tables for configuring the customer data block.
Attendant Console Options
Integrated Message Service Options
Call Redirection Options
Prompts Responses Description
REQ CHG Change existing data
TYPE ATT Attendant Consoles
CUST 0 Customer number
OPT MCI Message Center Included
ATDN (0) x...x Attendant Directory Number
Prompts Responses Description
REQ CHG Change existing data
TYPE IMS Integrated Message Service
CUST 0 Customer number
IMS YES Change Integrated Message System
IMA YES Integrated Message System enabled
Prompts Responses Description
REQ CHG Change existing data
TYPE RDR Call Redirection
CUST 0 Customer number
FNAD FDN Call Forward No Answer Treatment for
DID calls
FNAT FDN Call Forward No Answer Treatment for
External Trunk non-DID calls
FNAL FDN Call Forward No Answer Treatment
for all other calls including trunk calls
marked as internal
CFTA NO Call Forward to Trunk Access code