Cabling, installing, and configuring the peripheral devices 8-9
Installing the multiple administration terminals
Standard 1.0 Option 11 EC Installation and Maintenance Guide November 1999
Installing the multiple administration terminals
Installing MATs
Each EC11 installation includes a primary administration
terminal. In addition, optional multiple administration
terminals (MATs) can be used for non-critical administration
functions such as adding customers or configuring customer
options. You may install no more than one MAT per node.
Note: You must have the multiple administration terminals
feature installed.
To install a MAT, follow these steps.
The original installer or supplier of the installation software
should have configured a port for each MAT.
Step Action
1 Place the multiple administration terminal in a
suitable location.
The terminal should be installed within 15 m (50 ft.)
of the EC 11 system. If the distance is greater than
15 m (50 ft.), asynchronous limited distance
modems must be used.
2 Connect the keyboard and power cord to the
terminal.
3 Connect one end of a straight-through RS-232 cable
(NTND91AA/AB) to a null modem adapter
(NTND93AA). Connect the other end of the adapter
to the serial COMM or COMM1 connector on the
terminal. Use a gender changer as necessary
(A0351509).
4 Connect the free end of the cable to an RS-232 port
on the EC 11 that has already been configured for a
MAT. This could be a port on a utility card in either
node (on one of the 4-port fanout cable connectors),
or a port on the node 2 Enhanced MMP40 or
MMP40 card.
5 Plug the terminal cord into an AC receptacle, and
power on the terminal.
6 Configure the terminal as described in “Configuring
the administration terminal” on page 8-40.