15-10 Troubleshooting operational problems
Silent channels
Standard 1.0 Option 11 EC Installation and Maintenance Guide November 1999
What to do if calls
have no voice and do
not produce a SEER
If calls have no voice and there is no SEER response, follow
these steps.
4 a. Disable and unseat the MGate card in the Option
11 switch.
b. Reseat the MGate card.
c. Reenable the MGate card.
d. Initialize the Option 11 switch.
Note: This step will suspend call processing. It is not
recommended during peak business hours.
5 Replace the network loop cable.
6 Replace the voice card.
7 If these procedures are unsuccessful, contact your
Nortel support organization.
Step Action
1 Determine if ERR 3036 or ERR 3037 occur on the
Meridian 1.
2 If there is no change, replace the network loop
cable, the MGate card, or both.
3 If these procedures are unsuccessful, contact your
Nortel support organization.