14-18 Troubleshooting startup problems
System fails to start completely
Standard 1.0 Option 11 EC Installation and Maintenance Guide November 1999
Troubleshooting
stages 5, 6, or 7
start-up failure
Stages 5 and 6 should take up to five seconds each. Stage 7
should take up to two minutes. If the startup fails at this point
it could indicate that the Meridian Mail programs have been
read incorrectly from the disk, or that the program on the disk
is incorrect or corrupted. To proceed, follow these steps.
Troubleshooting stage
8 startup failure
If the startup fails during stage 8, follow these steps.
Troubleshooting stage
9 startup failure
If the startup fails during stage 9, follow these steps.
4 If the startup display shows error messages such as
“bus error,” this can indicate a serious problem with
the SCSI disk. Contact your Nortel support
organization.
Step Action
1 Attempt to restart the system.
If the startup fails at the same point, there could be a
serious problem with the SCSI disk.
2 Contact your Nortel support organization.
Step Action
1 Check the terminal output during this stage.
2 If there is an indication that the PRM failed to load,
contact your Nortel support organization.
Step Action
1 Check the terminal output during this stage.
2 If there is an indication that SEERs may be lost,
power the system down and power it back up to
reset the system.
3 If the startup still fails at the same point, replace the
Enhanced MMP40 or MMP40 card of the affected
node.