Additional References
HP-UX version 11.00.01 Configuring Asynchronous Serial Interfaces 7-9
■ If modems connect to each other, but no data appears, turn off all compression,
reliability, MNP, PEP, LAP, and other advanced features. Set the modem as
simply as possible. Once working, add the advanced features.
■ Do not use CCITT control signals on either modem or system. This does not
affect the modem use of CCITT modulation or compression standards such as
V.22, V.32, V.22bis, V.32bis, V34, V.42, or V.42bis.
■ Save modem settings in nonvolatile modem memory so modem retains the
setup after power loss. (Use AT&W on Hayes modems.)
■ Record modem settings on a worksheet for future reference.
See the mksf(1M), modem(7), and termio(7) man pages for bit values and use.
Additional References
In addition to the material furnished in the manual, you can consult the following
references:
■ PCI card installation and operation documentation
■ HP-UX Operating System: Fault Tolerant System Administration (R1004H)
■ the mksf(1M), insf(1M), stty(1M), modem(7), and termiox(7) man pages
■ DTC Device File Access Utilities and Telnet Port Identification (B1030-90002)