Configuring Console Controller Serial Ports
3-2 Peripherals Configuration (R1001H) HP-UX version 11.00.01
The console controllers support three serial ports, a console port, a port reserved
for the RSN modem, and an auxiliary port that you can use for various purposes
(for example, an external UPS). The ports are located on the back of the system base
or cabinet in a Continuum system. The port assignments are as follows:
Port 0 Console
Port 1 Remote Service Network (RSN)
Port 2 Auxiliary port (for UPS or secondary console)
By default, the ports are configured as shown in Table 3-1.
Normally, you do not need to change these settings. However, you can change a
port configuration by burning a new config partition in the console controller.
To burn a new config partition, do the following:
1. Check your console terminal manual, and any other devices that you need to
connect to one of the serial ports, to determine the correct line settings.
2. Determine which console controller is on standby. To do this, enter
ftsmaint ls 1/0
ftsmaint ls 1/1
Look for Online Standby in the Status column; this state identifies the
standby console controller (the online controller lists an Online state). Note
the location, either 1/0 or 1/1 in the H/W Path column.
NOTE
You must specify the standby board for any console controller
board-burning commands. You will get an error if you specify the online
board.
Table 3-1. Console, RSN, and Auxiliary Port Configuration
Console Port RSN Port Auxiliary Port Auxiliary Port for
UPS
9600 baud 9600 baud 9600 baud 2400 baud
7 bits 7 bits 7 bits 8 bits
odd parity odd parity odd parity no parity
1 stop bit 1 stop bit 1 stop bit 1 stop bit