Seagate ST39175LW Guía de usuario Pagina 40

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 104
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 39
Fibre Channel Mapping Examples
30 NetBackup ServerFree Agent System Administrators Guide
Fibre Channel Mapping Examples
The following examples contain SCSI-to-fibre bridges and show the SCSI-to-fibre-channel
mappings in various configurations. In these examples:
HBA is a host bus adapter.
FC LUN is a fibre-channel lun.
The UNIX pass-through paths do not need to start at c0. The paths shown are only
examples and can be any adapter number. These paths are used when configuring the
NetBackup sg driver on Solaris hosts.
Example 1
This example consists of two tape drives, a disk drive, a SCSI-to-fibre bridge, a hub or
switch, and a host bus adapter (HBA) on the NetBackup client.
The following table shows the device names and the device paths that you would use
when configuring the drives in this example:
Table 2. One Bridge - One HBA
SCSI
ID
FC
LUN
SCSI Coordinates
(Port Bus Target
LUN)
Device Path
(UNIX)
Pass-thru Path
(Solaris)
1 0 0 0 0 0 /dev/rmt/0cbn /dev/sg/c0t0l0
2 1 0 0 0 1 /dev/rmt/1cbn /dev/sg/c0t0l1
3 2 0 0 0 2 /dev/rdsk/c0t0l2 /dev/sg/c0t0l2
NetBackup Client
Fibre
Channel
Bridge
Drives containing
client data
Fibre
Channel
HBA
2
3
1
2
0
1
SCSI
Media
Server
Hub or
Switch
(optional)
LUNs
SCSI
IDs
HBA
NetBackup 4.0V ServerFree Agent System Administrator's Guide for Solaris
NetBackup 4.0V ServerFree Agent System Administrator's Guide for Solaris