KZPSA PCI-to-SCSI Storage Adapter
6–2 EK–KZPSA–UG. B01
NOTE
Refer to the
Release Notes
for the minimum revi-
sion levels of the ARC firmware.
Select Run a program from the Boot menu. Place the utilities diskette into the
floppy drive. If you want to invoke the configuration/diagnostic utility, type
a:\cnfgdiag.exe <cr> at the “Program to run” prompt. If you want to in-
voke the firmware update utility, type a:\fwupdate.exe <cr> at the
“Program to run” prompt.
6.2 Configuration and Diagnostic Utility
The following keys do most of the basic operations to the utility:
Table 6–1 Keyboard Functions
Key Function
Arrow
Select items in a menu and manipulate the cursor.
Spacebar
Toggle a highlighted entry.
Enter
Select a highlighted entry.
Escape
Exit out of current window / stop a diagnostic test.
The KZPSA configuration and diagnostic utility (cnfgdiag.exe) allows you to
configure and test your KZPSA adapter by displaying the following information:
• Adapter Specific Parameters:
– Firmware and hardware revisions
– KZPSA SCSI ID
– Termpower status
– Termination status
– KZPSA virtual slot location
– SCSI devices connected to the KZPSA