22.122
Command Line Interface Reference InForm OS Version 2.2.4
■ To limit the performance impact of Remote Copy on the rest of the InServ storage system,
the number of volumes that are concurrently synchronizing is limited to 20 volumes.
This limit is not user-configurable and applies to the initial synchronization as well as
subsequent resynchronizations for synchronous as well as asynchronous periodic groups.
For example, if there are 30 volumes in asynchronous periodic mode that are being
resynchronized, you might notice that 10 volumes do not start synchronizing until the first
20 have completed. This can be seen by monitoring the
Sync% column of the showrcopy
command output.