20.3
InForm OS Version 2.2.4 Command Line Interface Reference
resetfc
For DC3 cages, soft reset the Fibre Channel interface card.
For DC2 and DC4 cages, soft reset the cage. FC-AL specifier is ignored.
hresetfc
For DC3 cages, hard reset the Fibre Channel interface card.
For DC2 and DC4 cages, hard reset the cage. FC-AL specifier is ignored.
remove
Remove the indicated drive cage (indicated with the <cage_name> specifier) from the
system. If this subcommand is used, the
a|b or 0|1 port specifier is not required. This
command fails when the cage has active ports or is in use. Permitted for Super user only.
clearlog
For DC2 and DC4 cages, clear the log in the cage. FC-AL specifier is ignored.
For DC3 cages, clearlog is not supported.
OPTIONS
–f
Forces the operation. When this option is not used, the command requires confirmation
before proceeding.
–ovrd
Forces the specified physical disk path offline even if it is the last remaining path.
SPECIFIERS
a|b
Specifies the side of the specified DC3 drive cage to be serviced. This specifier is not
required.
0|1
Specifies the side of the specified DC2 or DC4 drive cage to be serviced. This specifier is not
required.
<cage_name>
Specifies the name of the drive cage to be serviced.