Vista de pagina 122
10.17
InForm OS Version 2.2.4 Command Line Interface Reference
<speed> half|full
Use only with the rcip speed subcommand. Specifies the speed setting (10, 100, or 1000)
and duplex setting (
half or full) for a Remote Copy interface. In addition to this
specifier, you must also specify an interface using
<node:slot:port>. If no speed or
duplex settings are specified, or if you specify
auto with the rcip speed subcommand,
the system auto-negotiates the speed and duplex.
RESTRICTIONS
The –m <mode> option for the rst subcommand cannot be specified if there are active
connections already using the port (that is the port online) except as noted in the following
section under port pair protection.
Port pair protection:
For dual-port LSI Fibre Channel adapters, both ports in the pair must use the same mode
(initiator or target).
For quad-port LSI Fibre Channel adapters, each ports pair (ports 1 and 2, ports 3 and 4)
must use the same mode.
Changing the mode of one port in a pair (for example, from initiator to target) causes
the other port in the pair to undergo a mode change as well.
If there are active hosts or physical disks when issuing the controlport rst or offline
commands, a warning is returned and you are prompted for confirmation to complete the
execution of the commands.
When issuing the controlport ct, cl2, rate, persona, or rscn commands, if there are
active disks on the port, an error is returned. If there are active hosts on the port, the
–f
option is overridden (if specified), a warning is returned, and you are prompted for
confirmation to complete the execution of the commands.
CAUTION: Use caution when changing modes for ports in LSI Fibre Channel
adapters. Changing the mode of one port in a pair (for example, from initiator to
target) causes the other port in the pair to undergo a mode change. In the case
where one port in the pair is offline (and therefore a mode change can be
allowed), but the partner port is online, changing the mode of the offline port
causes the online partner port to undergo a mode change as well. This results in
loss of use of the partner port because it is no longer online.