Seagate ST3400071FC Guía de usuario Pagina 136

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 718
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 135
11.10
Command Line Interface Reference InForm OS Version 2.2.4
–ssz <size_number_chunklet>
Specifies the set size in number of chunklets. The default set size is 2 for RAID-1, 4 for RAID-
5. If not specified, the default set size is used by the showspace command to estimate
space available.
–rs <size>
Specifies the number of sets in a row. The default is no row limit.
–ss <sizeKB>
Specifies the step size from 32 KB to 512 KB. The step size should be a power of 2 and a
multiple of 32. If no value is entered, the step size defaults to 256 KB for RAID 0 and RAID 1,
and 128 KB for RAID 5.
–ha port|cage|mag
RAID-1 or RAID-5 can support a failure of one port pair, one cage, or mag. For RAID-1 and
RAID-5 the user default, snap admin and snap data areas are cage. For RAID-0 the default
for the snap admin area is cage.
–ch first|last
Specifies the chunklet characteristics, either first (fastest chunklets) or last (slowest
chunklets). If no argument is specified, the default characteristic is
first.
-f
Does not ask for confirmation before creating a RAID-0 volume.
–wait <ts>
Waits for the specified number of seconds (<ts>) for the chunklets to initialize. The default
is computed automatically.
–dr
Specifies that the command is a dry run and that no logical disks or virtual volumes are
actually created.
–verbose on|off
Specifies that verbose output is either enabled (on) or disabled (off).
–cnt <number_of_VV>
Specifies the number of identical virtual volumes to create using an integer from 1 through
999. If not specified, one virtual volume is created.
Vista de pagina 135
1 2 ... 131 132 133 134 135 136 137 138 139 140 141 ... 717 718

Comentarios a estos manuales