14 Elite 23 Installation Guide, Rev. A
Table 2: DC power requirements
1
Measured with an average reading DC ammeter. Instanta-
neous +12V current peaks will exceed these values.
2
A –10% tolerance is permissible during initial start of the spin-
dle but must return to ±5% before reaching 5400 r/min. The
±5% must be maintained after the drive signifies that its
power-up sequence has been completed and that the drive is
able to accept selection by the host initiator.
3
See the +12V current profile in the
Elite 23 Product Manual
(publication number 83329140).
4
This condition occurs when the Motor Start option is enabled
and the drive has not yet received a Start Motor command.
5
See “Conducted noise immunity” in the
Elite 23 Product Man-
ual.
The specified voltage tolerance is inclusive of ripple,
noise, and transient response.
Single-ended Differential
+5V
8
,
10
± 5%
+12V
8
± 5%
2
+5V
8
,
10
± 5%
+12V
8
± 5%
2
Voltage regulation
5
Amps
Maximum starting current
Peak DC
3, 6, 9
1.0 4.8 1.05 4.8
Delayed motor start (max)
1, 4
.85 .1 .85 .1
Peak operating current
Typical DC
1
Maximum (peak)
7
.98
1.1
1.6
2.8
1.2
1.95
1.6
2.8