DVR User’s Manual
41
4.5.2 Dome Protocol Setup
The Dome Protocol lists the supported dome protocols for communicating
with dome cameras connected to the DVR. From the Main menu, select
<Camera> and press ENTER. To configure dome protocol, select a camera
first and set the communication protocol associated with dome camera using
the Direction keys and ENTER.
Analog Camera
Analog Camera Select
Dome Protocol
Dome ID
Camera Title
Covert
Termination
Brightness
Contrast
Saturation
Hue
Audio Association
Copy Settings
CH01
None
0
Ch1
On
0
0
0
0
Yes
NOTE: The settings become effective after saving the changes and
exiting from the menu.
4.5.3 RS485 Setup
The DVR controls the dome cameras via RS-485 communication protocol.
The RS-485 parameters of the DVR must be set to the same as the
parameters set in dome camera.
Users are allowed to change the RS-485 settings of the DVR. Select
<System> in Main menu, then select <RS485 Setup> from the System setup
menu and press ENTER. The following menu is displayed.
RS485 Setup
Unit ID
Baud Rate
Bits
Stop
Parity
224
9600
8
1
None
Unit ID number must match the ID address set by the dome camera. The Unit
ID is in the range of 1 to 255. Note that there cannot be any two devices on
the same bus given the same ID address, or a conflict may occur.