16 SVA Path User’s Guide
How to Verify Load
Balancing
In Figure 3-4, “Example setsp -a Output in Determining Load
Balancing”, there are four SVA Path devices;
spd0, spd1, spd2
and spd3.
Figure 3-4 Example setsp -a Output in Determining Load
Balancing
• Status shows the current state of the path. Good paths are
functioning normally. Bad paths have failed. Excluded
paths are unavailable to applications on this host.
# setsp -a
===============================================================================
spd Path/disk Status Primary Exclude Buf Balance RtrCnt RtrDly FailBack
===============================================================================
0 c0t1d0 Good X 32 1 20 3000 1
c3t0d0 Excluded X
spd0 = c83t0d0 ID = "STK 9500 0000000010390000"
===============================================================================
1 c0t1d1 Good 32 1 20 3000 1
c3t0d1 Good X
spd1 = c83t0d1 ID = "STK 9500 0000000010390001"
===============================================================================
2 c0t1d2 Good X 32 1 20 3000 1
c3t0d2 Good
spd2 = c83t0d2 ID = "STK 9500 0000000010390002"
===============================================================================