Chapter 7, Extended Frozen Image Services (Array Integration Option) 107
Configuring Primary and Secondary Disks
LU-M
LU indicates the SCSI or fibre channel logical unit number of the disk, configured by
means of the array’s dedicated console (not from a NetBackup host). M is the numeric
mirror descriptor for cascading disks. A cascading disk has more than one mirror
(secondary) associated with a given primary.
Seq#
This is the unit serial number of the array.
LDEV#
Logical device number of the disk.
P/S
Indicates whether or not the disk is configured in a primary-secondary pair:
◆ P-VOL: the disk is the primary.
◆ S-VOL: the disk is the secondary.
◆ SMPL: the disk is not paired (associated) with any other disk.
Status
Shows the current state of each disk in the array:
◆ PAIR: the secondary disk in the pair is synchronized with the primary.
◆ PSUS: the pair is split (primary disk).
◆ SSUS: the pair is split (secondary disk).
◆ COPY: a synch or split is in progress. If synchronizing, the status changes to PAIR at
completion of the COPY; if splitting, the result is PSUS for primary disk, or SSUS for
secondary disk.
Note If a backup is attempted while a disk is split (PSUS, SSUS), the backup fails with a
status code 11. If a backup is attempted while a disk is in the COPY state, there are
two possible results: if the disks synchronize (shown as PAIR), the backup
proceeds; if the disks split (PSUS, SSUS), the backup fails with a status code 11.
%