5
Note:
The EMP has an 800mA +5V Standby power requirement. The
L440GX+ Server Board must be powered whenever the server
system is plugged in. Ensure the power supply selected to
power your integrated L440GX+ server system fulfills this
power requirement. Refer to the tested chassis and power
supply summary at Error! Reference source not found.
Server Set up:
Hardware configuration used:
Intel L440GX+ Server Board, Intel Astor II server chassis, two Intel Pentium II Processors with 100MHz
System Bus, operating at 400MHz, 64MB Samsung* PC/100-compliant 100MHz SDRAM (one 64MB
168pin Gold DIMM), 5 Seagate* ST32550WC Barracuda* Hard Disk Drives, Hitachi* 24xIDE CD-ROM,
Teac* Floppy diskette drive, 3Com* US Robotics* Sportster* 28.8 external modem.
1. If intending to use the Real Server remote capability of the EMP through a modem, connect an external
modem capable of 19.2 KBPS to the Servers COM2 port.
2. Power on the L440GX+ server system, pressing <F2> prior to completion of POST (Power On Self-
Test) in order to enter BIOS Set-up.
3. Using the left/right cursor arrow keys select the tab menu labeled Server.
4. Using the down cursor arrow key select System Management” and press <Enter>.
5. Select EMP Password Switchto <Enabled>.
6. Select EMP Password” and enter the password to be used for that particular server from the EMP
Console utility.
7. Leave the following selectable fields as default, for further details on these options use refer to the
L440GX+ Product Guide:
“EMP ESC Sequence”
“EMP Hangup Line String”
“Modem Init String”
“High Modem Init String”
8. Select EMP Access Modeto <Always Active>. Available modes include:
Always active - the COM2 Port is always used by the EMP and invisible to the Operating System
(recommended for full functionality).
Pre-Boot - EMP only has control of the COM2 port when the server is powered down or prior to the
completion of POST.
Disabled – EMP is unavailable.
9. Select EMP Restricted Access” to <Disabled>. Available options include:
Enabled - prevents power down and reset control via the EMP.
Disabled – all EMP capabilities are available.
10. Select EMP Direct Connect/Modem Modeto <Modem>. Available options include:
Modem – external modem connected to COM2 port.
Direct Connect – serial-serial connection between servers COM2 port and PC running the EMP
Console utility.
11. Select <ESC> to back up to the “Server” menu
12. Select “Console Redirection”
13. Select “Com Port Address” and select <2F8>, the address for COM2. EMP requires COM2 to
function properly.
14. Select “Baud Rate” as <19.2K>, this is required for proper communication between the Baseboard
Management Controller (BMC) and the modem via the Super I/O controller.