Global Certification Corp.
Date of Issue: SEP.13,2007
Report No:F790506
Page11/16
3. CONDUCTED EMISSION MEASUREMENT
3.1 TEST SET-UP (PLEASE REFER TO APPENDIX 1)
3.2 LIMIT
CLASS A CLASS B
Frequency range
(MHz)
QP
dB(uV)
Average
dB(uV)
QP
dB(uV)
Average
dB(uV)
0.15-0.5
79 dBuV 66 dBuV
66 - 56 dBuV 56 - 46 dBuV
0.5-5.0
73 dBuV 60 dBuV
56 dBuV 46 dBuV
5.0-30.0
73 dBuV 60 dBuV
60 dBuV 50 dBuV
Remark: In the above table, the tighter limit applies at the band edges.
3.3 TEST PROCEDURE
The EUT and simulators are connected to the main power through a line impedance
stabilization network (LISN). It provides a 50 ohm / 50 µH coupling impedance for the
measuring equipment. The peripheral devices are also connected to the main power through a
LISN that provides a 50 ohm / 50 µH coupling impedance with 50 ohm termination. (Please
refer to the block diagram of the test setup and photograph.)
Both sides of AC line are checked for the maximum conducted emission interference. In
order to find the maximum emissions, the relating positions of equipment and all of the
interference cables must be changed according to CISPR22 regulation: The measurement
procedure on conducted emission interference.
The resolution bandwidth of the field strength meter is set at 9KHz
LISN LISN
EUT
Load
VCP
HCP
80cm
Non-Conduc
ive Table
Receive